        <article-title>30Cr2Ni4MoV 阀杆锻件力学性能不合格原因分析</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>李顺阳 （忻州市综合检验检测中心 山西忻州 034000）</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2026</year>
        <month>3</month>
      </pub-date>
      <issue>3</issue>
      <abstract>
        <p>通过化学成分、气体含量、拉伸试验、夏比冲击试验和金相分析，对 30Cr2Ni4MoV 阀杆用合金钢锻件力学性能不 合格原因进行研究。结果表明：阀杆锻件的化学成分符合标准要求但氢含量高；力学性能抗拉强度(1347MPa)和屈服强度 (1288MPa)满足企业标准要求，但断面收缩率、断后伸长率和冲击功均不符合标准要求；布氏硬度结果平均值为 431，高于 标准要求 380-420。结合金相分析得出以下结论：材料在调质前未正火，组织不均匀；调质处理时高温回火温度不足，导致 阀杆锻件的内应力过大，材料韧性差，保温时间不够导致布氏硬度数值高；此外，检测出氢含量较高，锻件内部产生细小白 点，夹杂物数量多且较大，在拉力作用下出现应力集中发生脆断。</p>