        <p>面向高负荷乘客电梯，研究构建“感知-传输-分析”三层电梯物联网 PHM 检验框架，感知层以 200Hz 振动、1Hz 温度/电流同步采集，边缘完成异常剔除与事件分段；传输层采用 MQTT+TLS+QoS 保障弱网环境下的时序一致；分析层融 合随机森林与自适应阈值，输出部件-系统两级健康指数。30 天实验显示事件级预测准确率 95.2%，故障预警提前 24h，检 出率较传统周期巡检提升 30%，停运时间呈持续下降趋势，验证了高负荷场景下零侵入、可迁移的前瞻维护可行性。</p>