        <article-title>硝酸磁力泵隔离套频繁泄漏问题的分析与改进</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>孙国松 （国家能源集团新疆哈密能源化工有限公司）</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>4</month>
      </pub-date>
      <issue>4</issue>
      <abstract>
        <p>本文针对某煤化工企业储运装置 3 台磁力泵硝酸给料泵（2411-P-04A/B）、硝酸卸料泵（2411-P-03）（以下简称硝酸磁力泵）隔离套频繁泄漏问题，通过分析研判历次检维修记录、参照设备运行参数、操作步骤、备品备件质量等原因，发现原隔离套材质哈氏合金 C-276耐 68wt%硝酸溶液腐蚀性低是导致泄漏的主要原因。结合设备厂家提供的腐蚀数据，将隔离套材质更换为钛合金，并优化备品备件采购、验收、维护管理等措施，隔离套使用寿命延长 8 倍有余，有效降低了非计划停机率，提升装置连续运行的稳定性，为下游装置连续供料提供强有力的保障，其中该改进方案《降低磁力泵故障率、提升机泵运行效率》获得该企业五小成果优秀奖，证明了该改进措施的有效性和合理性。</p>