      <abstract>
        <p>工业废水常含高浓度盐分，采用 ICP-OES 测定其中硫酸根时易受基体干扰，导致结果偏低。本研究以工业废水中主要盐分组分钠离子为研究对象，考察不同钠离子浓度对硫酸根测定的影响。结果表明，当钠离子浓度超过 1000 mg/L 时，对硫酸根测定产生明显负干扰，且干扰程度随浓度升高而加剧。采用直接稀释法可有效消除 10000 mg/L 以内钠离子的干扰。该方法操作简单、结果稳定可靠，适用于高盐分工业废水样品中硫酸根的快速准确测定。</p>
      </abstract>