        <article-title>同步发电机励磁机电枢绕组并头套断裂故障分析与治理</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>王子洋 中国石化公司茂名分公司</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2026</year>
        <month>2</month>
      </pub-date>
      <issue>2</issue>
      <abstract>
        <p>针对某石化企业 3#发电机因励磁机转子电枢绕组并头套与连接环接头断裂引发失磁保护动作跳闸的典型故障，结合故障录波、现场解体、材料理化测试及微观断口分析，系统还原故障全过程并揭示失效机理。结果表明：母材材质合格，故障根源为并头套采用搪锡工艺存在焊接填充不密实、接触电阻大、耐热性差等缺陷，在转子高速旋转交变载荷作用下发生疲劳断裂，最终导致励磁回路中断、机组失磁停机。提出建议以银基钎焊替代搪锡、停机孔探检测、每 8 年大修检查等综合治理措施，可为同类型无刷励磁发电机电枢端部连接结构故障防控提供工程参考。</p>