        <p>某燃油电厂钢结构厂房长轴方向长度约 110m，宽度方向约 45m，总高度为 42m。本文采用 SAP2000 建立有限元分析模型，并采用
美标进行结构设计。本文详细介绍了钢结构厂房采用美标进行结构设计的过程和要点，包括美标参数和地震荷载的取值。对厂房结构进行
变形和强度校验，计算结果表明：结构地震采用反应谱法进行计算，结构的质量参与系数均大于 90%，发电厂房结构在地震作用下的最大
变形分别为 92mm 和 131mm，满足设计要求，构件的最大应力比为 0.9，满足设计要求。
关键字：发电厂厂房结构，美标设计，反应谱计算，应力计算</p>