      <title-group>
        <article-title>地铁车站侧墙混凝土早期温度场与应力变化规律探究</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>钱华平</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>8</month>
      </pub-date>
      <issue>8</issue>
      <abstract>
        <p>本研究以无锡地铁 5 号线清名古桥站为对象，针对 N13 段负三层侧墙混凝土，系统探究其早期温度场与应力变化规律。结合工程
概况，运用现场监测与数值模拟方法，分析混凝土在浇筑早期因水泥水化热引发的温度变化，以及由此产生的温度应力与收缩应力协同作
用机制。研究发现混凝土内部温度先升后降，表面与内部存在显著温差，应力在浇筑后 3-5d 达到峰值，威胁结构安全。研究成果可为优化
地铁车站侧墙混凝土施工工艺、预防裂缝产生提供科学依据，保障工程质量与耐久性。
关键词：地铁车站；侧墙混凝土；早期温度场；应力变化规律</p>