        <article-title>混凝土抗压强度检测结果偏差原因分析与控制措施研究</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>王光龙</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2024</year>
        <month>21</month>
      </pub-date>
      <issue>21</issue>
      <abstract>
        <p>混凝土抗压强度检测是工程质量控制的核心环节，其结果偏差可能导致结构安全评估失误。本文通过正交试验设计与现场实测数
据，系统分析样品制备、养护环境、设备性能等 8 大维度 23 项影响因素，建立检测偏差量化模型。研究表明，养护温湿度波动（贡献率 32.7%）
与压力机加载速率误差（贡献率 25.4%）为主要致偏因子。基于此，提出智能传感监测、设备动态校准、人员能力矩阵管理等创新控制措施，
并通过某跨海大桥工程案例验证，使检测结果标准差从 4.1MPa 降至 1.8MPa，为行业提供全流程质量控制解决方案。
关键词：混凝土；抗压强度；检测偏差；贡献率；智能控制</p>