        <p>本文围绕配电网的漏电保护与接地系统模式展开探讨，重点分析了乐电公司目前主要采用的 TN-C 系统存在的问题，包括 PEN
线断线引发触电风险、多点接地导致 RCD 误动或拒动等安全隐患，以及不完全 TN-C 系统仍存在的安全缺陷。对 TT 接地系统的可行性
进行了综合论证，指出其通过独立接地设计，能解决 TN-C 系统的固有缺陷，在安全、稳定、经济及政策层面具有优势。本文还探讨了
TT 系统推广面临的技术认知、建设标准、协调机制等挑战，并提出了强化培训、完善标准、试点先行等应对策略。
关键词：接地系统；漏电保护；TN-C 系统；TT 系统</p>