        <p>文章对烟气余热回收系统进行了介绍，通过文献调研，介绍了目前烟气余热回收利用技术的进展。介绍了某大型供热系统烟气余
热系统，并针对该系统锅炉烟气余热系统局限性进行分析，分析对比了两种改造方案，通过对比选取了最优方案并进行了改造工程价格估
算；通过测试及相关运行数据分析，得出改造后运行成本和维护成分析，最后得出结论，通过改造每年可回收使用热量 8925GJ，每供暖季
为节约标煤 314 吨。预计约 3 年时间回收改造成本。
关键词：集中供热系统；烟气余热回收；经济性分析</p>