      <abstract>
        <p>本文着重探讨超临界锅炉补给水制备环节里 EDI（电去离子）技术抗污染性能的增强问题。首先，阐述了 EDI 技术的工作原理、
特性，以及它在超临界锅炉补给水制备工作中所占据的关键地位。之后，深入分析了影响该技术抗污染性能的各类因素，像进水的水质状
况、膜材料的选用、运行参数的设定等。紧接着，给出了提升抗污染性能的针对性举措，例如对预处理工艺加以优化、对膜材料进行改良、
科学合理地调控运行参数等。最后，借助实际案例展开分析，以此验证所提策略的切实有效性，期望能为超临界锅炉补给水制备中 EDI 技
术的实际应用提供有益借鉴。
关键词：超临界锅炉；补给水制备；EDI 技术；抗污染性能；提升策略</p>