        <article-title>热电厂汽机给水泵断轴原因及措施探讨</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>李来勇 （国能河北衡丰发电有限责任公司 衡水市 053010）</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>5</month>
      </pub-date>
      <issue>5</issue>
      <abstract>
        <p>2023 年 7 月，华能临沂发电有限公司 1 号机组汽机给水泵 DG500-180 型汽机给水泵出现断轴情况，导致机组降
负荷运行。为明确断轴原因、避免类似事故发生，研究人员开展分析。经分析，断轴由材质性能缺陷、机械运行异常、安装
维护隐患三方面问题导致。据此提出优化材质管控、改进运行管理、提升安装检修技术的处理办法。结论显示，采取针对性
处理可解决断轴问题，保障给水泵及机组安全稳定运行，减少经济损失。</p>