        <article-title>汽轮机数字电液控制系统（DEH）在垃圾发电汽轮机组的应用与故障处理</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>王恒华 （重庆市永川区三峰环保发电有限公司 402160）</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2026</year>
        <month>3</month>
      </pub-date>
      <issue>3</issue>
      <abstract>
        <p>随着生活垃圾焚烧发电装机容量持续增长，汽轮机控制系统的稳定性直接关系到机组发电效率与电网安全。垃圾燃料热值波动大、机组启停频繁的运行特性，对 DEH 系统的调节性能提出了高于常规火电机组的要求。本文分析了 DEH系统在垃圾发电领域的应用特点与硬件配置，结合现场典型案例剖析了 LVDT 振动、甩负荷超速两类频发故障的诊断与处理流程，并提出了涵盖逻辑优化与液压改造的系统性改进措施。通过引入优化后的控制算法与增设 OPC 电磁阀，某 12MW机组最高飞升转速由 3268r/min 降至 3079r/min，为同类型机组提供了可复制的技术参考。</p>