        <article-title>THALES-435 型 DME 天线射频板渗水导致功率下降的故障维修 案例</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>欧哲瑞</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2024</year>
        <month>7</month>
      </pub-date>
      <issue>7</issue>
      <abstract>
        <p>该文介绍 THALES-435 型 DME 设备天线射频板渗水导致天线辐射性能大幅度下降后导致设备
transmitted power 参数告警的故障分析与处理。通过分析设备监控器 transmitted power 参数的来源和信号流
程，快速定位故障点。并通过加强天线射频板密封的方式，减少故障出现的概率。主要为 THALES-435
型 DME 设备维护人员提供设备故障时的处理思路，对设备的风险隐患管控提供一个经典的参考案例。</p>